Short answer: it depends on the foam and the structure. Open-cell PUR foam stops air leaks but lets water vapour through. With it, whether a vapour barrier is needed depends on whether the outer layers of the structure are open to water vapour diffusion. Closed-cell foam slows water vapour down by itself and usually does not need a separate vapour barrier. We explain how this works in roofs, walls, steel structures and floors, and how to prevent condensation and mould.
How moisture gets into insulation
The air inside is warmer and more humid than outside. In winter, water vapour moves out of the room in two ways:
- with air through cracks and leaks, which is how most moisture moves;
- by diffusion slowly through the materials.
When damp air or water vapour reaches a surface that is colder than the dew point of the air, the vapour turns into water. This is called condensation. If the moisture cannot dry out, wood can begin to rot and mould can grow on surfaces.
PUR foam sticks to the surface and fills the cracks, so it closes the first route: moisture carried by air cannot get into the insulation. The second route, diffusion, depends on the type of foam.
Difference between open-cell and closed-cell foam
Water vapour permeability is indicated by the water vapour resistance factor μ. The higher this is, the less water vapour the material allows to pass through. The total resistance Sd of the layer also depends on the thickness of the layer: Sd = μ × layer thickness in metres.
| H2Foam Lite+ (open-cell) | Heatlok Shield (closed-cell) | |
|---|---|---|
| Water vapour resistance factor μ | 2 | 46 |
| Typical layer | 200 mm | 100 mm |
| Vapour resistance of the layer Sd | 0.4 m | 4.6 m |
| Stops air leaks | yes | yes |
| Is a separate vapour barrier needed? | depends on the structure | usually not |
Open-cell foam is airtight, but allows water vapour to pass through. This is not a defect, because that way water vapour does not get trapped in the structure. However, it must then be ensured that the outer layers are also open to water vapour diffusion.
Basic rule: tighter on the inside, more open on the outside
Water vapour must be able to escape from the structure towards the cold side. Therefore, the warm, room-side layer must allow less water vapour to pass through than the outer layers. If there is a vapour-tight layer on the outside, such as a bitumen covering or metal roof covering, and there is open-cell foam on the room side without a vapour barrier, moisture can accumulate on the inner surface of the outer layer.
A vapour barrier is a room-side membrane that slows the movement of water vapour into the structure. Builders' merchants sell two types of vapour barrier: a standard vapour barrier membrane that lets practically no water vapour through (Sd over 40 m), and a humidity-variable vapour barrier whose vapour resistance changes with humidity (Sd about 0.25 to 25 m). In winter, a humidity-variable vapour barrier is tighter to water vapour, and in summer it is more open.
Sloped ceiling and attic
Most often we install open-cell foam in sloped ceilings between the rafters, usually 200 to 250 mm. The need for a vapour barrier depends on what is above and below the foam.
- The roof is ventilated and the underlay is open to water vapour diffusion. Water vapour can continue outwards. Above living spaces, however, we still recommend a vapour barrier on the room side; a humidity-variable vapour barrier is also suitable.
- There is no ventilation, for example the underlay is directly under the roof covering or the roof has a bitumen covering. Then a room-side vapour barrier is needed.
- The roof is insulated from the outside during roof covering replacement. If there is a vapour-tight vapour barrier on the room side, no ventilation gap is needed above the foam. If the room-side layer lets vapour through, the roof must be ventilated.
In 2024, the UK building safety regulator HSE used a study to model pitched roofs insulated with sprayed foam. The risk was lowest when there was a vapour barrier on the warm side of the open-cell foam and the roof was ventilated. Without a vapour barrier, the risk was higher, especially if the underlay strongly restricted water vapour. The risk was highest when the foam was sprayed directly under the roof tiles. Estonian winters are colder than British ones, so these risks should not be underestimated.
In a cold loft, where the foam lies on top of the ceiling and the loft is ventilated, water vapour gets into the loft and escapes through the ventilation. The main thing there is that the ceiling is airtight and the loft ventilation is in working order. Above damp rooms, such as a bathroom or sauna, we take moisture into account separately.
For a roof without roofing underlay, such as an old fibre-cement roof, we recommend fixing a spacer batten to the edge of the rafter and a wind barrier on top of it before applying the foam, so that the roof ventilation is maintained. Read more: roof and loft insulation.
Walls
Timber frame house. Open-cell foam is well suited for filling between the studs. On the outside of a timber frame wall there is usually a vapour-permeable wind barrier board and, behind it, external cladding with a ventilation gap, so water vapour can escape outwards. We assess the need for a room-side vapour barrier for each project.
Stone and concrete walls. We often insulate these with closed-cell foam, which slows water vapour down by itself. A separate vapour barrier is usually not needed.
Log house. We insulate log houses with open-cell foam, usually from the outside. Read more: insulating a log house with PUR foam and wall insulation.
Metal structures, containers and hangars
Metal is vapour-impermeable and cools down quickly in winter. When warm, moist air reaches the cold metal, condensation occurs. Closed-cell foam adheres to the metal, leaves no gap for air and inhibits water vapour. Therefore, we mostly use closed-cell foam on metal structures. See also shipping container insulation and insulation of industrial buildings and hangars.
Floor from underneath
If the floor is insulated from below, for example in a house with a pillar foundation, moisture can come from the ground. In that case, the open-cell foam is covered on the ground side with a vapour barrier membrane if necessary. Read more: floor insulation.
How to prevent condensation and mould
- Dry substrate. According to the Huntsman installation manual, the wood must be dry before spraying, with a moisture content of up to 19%.
- Continuous foam layer. In HSE modelling, even a 1 mm air gap significantly increased the moisture risk. The foam must adhere to the surface completely and without cracks.
- Intact roof. If water gets through the roof covering, it gets trapped behind the insulation. According to the HSE, this risk is highest with closed-cell foam.
- Room ventilation. Humid indoor air must be extracted, because an airtight house requires a functioning ventilation system.
- Correct layer order. Tighter on the inside, more open on the outside.
PUR foam is not a food source for mould, but if there is moisture, mould can grow on wood or on dust that has collected on the foam surface. Read about wood rot and ventilation in the article PUR foam, moisture, ventilation and wood rot.
Who installs the vapour barrier?
We only install PUR foam, and we do not install a vapour barrier. The vapour barrier is installed by the interior contractor after the foam has been applied. Before starting work, we will review the layers and advise on the correct layer sequence for your house.
Frequently asked questions
Does PUR foam replace the vapour barrier?
Closed-cell foam slows water vapour down by itself and in many places does not need a separate vapour barrier. Open-cell foam stops air leaks, but it does not replace a vapour barrier.
Can PUR foam be installed without a vapour barrier?
Yes, if water vapour can escape outwards from the structure: the outer layers let vapour through and, where needed, the roof is ventilated. If there is a vapour-tight layer on the outside or no ventilation, a room-side vapour barrier is needed.
Does PUR foam go mouldy?
The foam itself is not a food source for mould. Mould needs long-term moisture, so the correct layer order, an intact roof and working ventilation are important.
Send us the area and layer thickness, and describe what is on the room side and what is on the outside. We will put together a personal quote for you and let you know whether your structure needs a vapour barrier. Request a quote or see PUR foam prices.