COMPARISON

PUR foam, wool or board: which insulation should you choose?

We compare PUR foam with insulation products common in Estonia in three places: foundations, walls, and sloped ceilings and attics. The figures come from manufacturers' data; we calculated the R-value and required thickness ourselves.

Reading time 6 min · Data as of 18/10/2026
Briefly
For the foundation, closed-cell PUR foam provides the same thermal insulation with a 108 mm layer. With XPS and EPS boards, a 150 mm layer must be installed for this.
The thermal conductivity is similar for both the roof and the walls. The difference is that PUR foam leaves no joints, does not sag, and keeps air out of the structure.
Huntsman's 25-year manufacturer's warranty covers both the material and the installation.
The total cost including extra layers and labour with rock wool and insulation boards is up to 2 times higher than with PUR foam at Passiivsoojustus prices.
The comparison applies to PUR foam installed by Passiivsoojustus

Prices, products, thermal conductivity and the 25-year warranty of PUR foam in this comparison belong to Passiivsoojustus. We install Huntsman H2Foam Lite+, H2Foam Lite V24 and Heatlok Shield foam. Prices, products, their indicators and warranty conditions of other PUR foam installers may differ.

When comparing quotes, ask the installer for the product name, declaration of performance (DoP) and a written warranty.

FOUNDATION AND PLINTH

Closed-cell PUR foam, XPS and EPS

The foundation has insulation against the ground and moisture. Here, what matters is how thin a layer can achieve the desired thermal resistance and whether the material can withstand water.

Property INSTALLED BY PASSIIVSOOJUSTUSPUR foam, closed cellHuntsman Heatlok Shield XPS boardFinnfoam FL-300 EPS boardEstplast EPS 120 Perimeeter Pluss
Thermal conductivity λD, W/mK
0,027
0,036 0,035
R value with 100 mm layer, m²K/W
3,70
2,78 2,86
Layer required for the same result, R 4.0
108 mm
140 mm2 × 70 mm, R 4.00 according to DoP 140 mm
Layer actually installed
108 mmsprayed to the required thickness
150 mm100 + 50 mm boards, 70 mm boards were not available in shops 150 mmboards 100 + 50 mm
Water absorption
Closed cell, water is not absorbed
0.7% with prolonged soaking 1.5% with prolonged soaking
Joints and uneven surface
Even layer, fills in irregularities
Board joints, a gap remains on an uneven surface Board joints, a gap remains on an uneven surface
Fixing
Adheres directly to concrete and stone
Glued or backfilled Glued or backfilled
Reaction to fire
E
F E
Warranty
25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman
Check the manufacturer's and installer's terms Check the manufacturer's and installer's terms

Product names are linked to the manufacturer's declaration of performance. Data as of 18/10/2026.

Total cost per square metrematerial including cutting waste, extra layers and labour
Heatlok Shield 108 mm
Passiivsoojustus price
EPS 150 mm
about 1.4 times more expensive
XPS 150 mm
almost twice as expensive
For boards, 10% cutting waste, adhesive, wall plugs and two-layer installation have been factored in. For smaller jobs, a minimum charge applies, which may change the ratio. The cost of PUR foam has been calculated using Passiivsoojustus prices. Other installers' prices may differ.
An installed layer that gives the same result as our 108 mm Heatlok Shield
calculated layeris added because boards are sold in a fixed thickness
PUR foam, Heatlok Shield108 mm
sprayed to the required thickness
XPS, Finnfoam FL-300150 mm
calculated 140 mm (2 × 70 mm), boards 100 + 50 mm
EPS, Estplast EPS 120 Perimeeter Pluss150 mm
calculated 140 mm, boards 100 + 50 mm
Calculated according to the manufacturers' λ data.
Almost 30% thinner layer with the same result.

The foam adheres directly to concrete, covers pipe penetrations and corners, and the trench can be backfilled on the same day.

Foundation insulation →
WALLS

PUR foam, rock wool and EPS in the wall

The baseline is our standard wall layer, 200 mm of H2Foam Lite+. The table shows how thick another material must be to provide the same thermal insulation.

Property INSTALLED BY PASSIIVSOOJUSTUSPUR foam, open cellH2Foam Lite+ INSTALLED BY PASSIIVSOOJUSTUSPUR foam, closed cellHeatlok Shield Rock woolParoc Ultra EPS boardEstplast EPS 60
Thermal conductivity λD, W/mK
0,035
0,027
0,035 0,039
Layer required for the same result, R 5.7
200 mm
154 mm
200 mm 223 mm
Layer actually installed
200 mmsprayed to the required thickness
154 mmsprayed to the required thickness
200 mmboards 150 + 50 mm 250 mmboards 200 + 50 mm
Airtightness
Airtight layer without joints
Airtight layer without joints
Joints, requires a separate wind and vapour barrier Board joints must be sealed
Corners, cracks and penetrations
Fills gaps and cracks
Fills gaps and cracks
Cracks appear at the cut lines On an uneven surface, gaps remain
Over the years
Does not sag, adheres to the surface
Does not sag, adheres to the surface
According to the manufacturer, it will not sag Does not sag
Fixing
Adheres to wood, concrete, stone and metal
Adheres to wood, concrete, stone and metal
Requires a framework or fixings Glued or dowelled
Best suited
Timber frame and log walls
Stone walls and metal structures
Timber frame Rendered facade
Framing
Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap
Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap
The board width must match the framing spacing (565 mm board for 600 mm spacing); in uneven framing, each piece is cut to fit its respective gap Glued and dowelled to the substrate
Warranty
25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman
25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman
Check the manufacturer's and installer's terms Check the manufacturer's and installer's terms

Product names are linked to the manufacturer's declaration of performance. Data as of 18/10/2026.

Total cost per square metrematerial including cutting waste, extra layers and labour
Lite+ 200 mm
Passiivsoojustus price
EPS 250 mm
more than 1.5 times more expensive
Paroc Ultra 200 mm
up to 2 times more expensive
For wool and boards, 10% cutting waste, vapour barrier membrane and tapes, wind barrier board, battening and the installation of all layers have been taken into account. For smaller jobs, a minimum charge applies, which may change the ratio. The cost of PUR foam has been calculated using Passiivsoojustus prices. Other installers' prices may differ.
Installation time for 200 m² wallworking days, wool and board installation with two builders
Lite+ 200 mm
1 day
EPS 250 mm
about 7 working days
Paroc Ultra 200 mm
about 16 working days
The working time for mineral wool and boards has been calculated from the labour costs and hourly rates in construction companies' public price lists: installation of two layers of mineral wool, vapour barrier, wind barrier and battening for rock wool, and installation of two layers for EPS boards. The calculation is at the end of the page. The PUR foam time is a normal working day for Passiivsoojustus.
Same U-value as our 200 mm Lite+ wall (U 0.170)
calculated, level 0calculated, level 2is added due to the thickness of the boards
PUR foam, H2Foam Lite+200 mm
sprayed to the required thickness
Rock wool, Paroc Ultra200 to 260 mm
from boards: 200 to 300 mm
EPS board, Estplast EPS 60223 to 290 mm
from boards: 250 to 300 mm
Calculated according to standard EVS-EN ISO 6946: sprayed foam level 0, wool and boards level 0 to 2 (from tight joints to air gaps). Board thicknesses: Paroc Ultra and Estplast EPS 60 in stores with a 50 mm step.
The lab figure is the same, the result in the house is not.

The standard accounts for the fact that joints in wool and boards, as well as air gaps, reduce thermal insulation. Spray foam fills the surface as a single continuous layer without gaps.

Wall insulation →
SLOPED CEILING AND ATTIC

PUR foam, rock wool and cellulose wool in the ceiling

The reference standard is our standard ceiling layer, 250 mm H2Foam Lite+. The table shows how thick the other material must be to provide the same thermal insulation.

Property INSTALLED BY PASSIIVSOOJUSTUSPUR foam, open cellH2Foam Lite+ INSTALLED BY PASSIIVSOOJUSTUSPUR foam, open cellH2Foam Lite V24 Rock woolParoc Ultra Cellulose insulationEkovilla YP
Thermal conductivity λD, W/mK
0,035
0,038
0,035 0,038
The layer required for the same result, R 7.1
250 mm
271 mm
250 mm 271 mm
Layer actually installed
250 mmsprayed to the required thickness
271 mmsprayed to the required thickness
250 mmboards 150 + 100 mm 271 mmblown in to the required thickness
Airtightness
Airtight layer without joints
Airtight layer without joints
Joints, requires a separate wind and vapour barrier Requires a separate wind and vapour barrier
Corners, cracks and penetrations
Fills gaps and cracks
Fills gaps and cracks
Cracks appear at the cut lines Fills open cavities
Over the years
Does not sag, adheres to the surface
Does not sag, adheres to the surface
According to the manufacturer, it will not sag To be installed with a settlement allowance
Installation
Can be sprayed up to 500 m² per day
Can be sprayed up to 500 m² per day
Cut and installed by hand Blown in by machine
Framing
Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap
Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap
The board width must match the framing spacing (565 mm board for 600 mm spacing); in uneven framing, each piece is cut to fit its respective gap Requires a closed cavity, does not depend on the spacing
Warranty
25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman
25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman
Check the manufacturer's and installer's terms Check the manufacturer's and installer's terms

Product names are linked to the manufacturer's Declaration of Performance or product datasheet. Data as of 18/10/2026.

Total cost per square metrematerial including cutting waste, extra layers and labour
Lite+ 250 mm
Passiivsoojustus price
Paroc Ultra 250 mm
more than 1.5 times more expensive
For wool, 10% cutting waste, vapour barrier membrane and tapes, wind barrier fabric, battening and the installation of all layers have been taken into account. For smaller jobs, a minimum charge applies, which may change the ratio. The cost of PUR foam has been calculated using Passiivsoojustus prices. Other installers' prices may differ.
Installation time for a 200 m² ceilingworking days, insulation installation with two builders
Lite+ 250 mm
1 day
Paroc Ultra 250 mm
about 16 working days
The working time for insulation installation has been calculated using the labour and hourly rates from construction companies' public price lists: the installation of two layers, vapour barrier, wind barrier and battening. Loose-fill insulation is not included here, as it is machine-blown and its working time cannot be determined separately from the price lists. The calculation is at the bottom of the page. The PUR foam time is a normal working day for Passiivsoojustus.
Same U-value as our 250 mm Lite+ ceiling (U 0.137)
calculated, level 0calculated, level 2is added due to the thickness of the boards
PUR foam, H2Foam Lite+250 mm
sprayed to the required thickness
PUR foam, H2Foam Lite V24271 mm
sprayed to the required thickness
Rock wool, Paroc Ultra250 to 351 mm
from boards: 250 to 400 mm
Cellulose fibre insulation, Ekovilla YP271 mm
blown in to the required thickness
Calculated according to standard EVS-EN ISO 6946: sprayed foam and loose wool level 0, wool batts level 0 to 2 (from tight joints to air gaps). Paroc Ultra batts are available in stores with a 50 mm increment.
A layer that does not sag or let air through.

Lite+ provides the same result with a thinner layer. We use V24 in thicker layers, starting from 250 mm. Both adhere to rafters and boarding and do not sag over the years.

Roof and loft insulation →
25
years of manufacturer's warranty on materials and installationFollowing the completion of the work, we register the warranty and Huntsman sends a written certificate to the customer. Such a warranty can only be provided by a Huntsman-licensed installer.
What we included in the total cost

Materials: the average regular prices at Espak, Bauhof and Decora as of 6 October 2026, the price of EPS 120 Perimeeter Pluss foundation boards from Bauhof as of 18 October 2026, without promotional or loyalty card discounts. All prices are compared excluding VAT.

Additional layers for wool and boards: vapour barrier film in walls and ceiling (with 10% overlap) and vapour barrier tape at 0.5 m per square metre, wind barrier, 50×50 mm battens at 600 mm centres. On the foundation, adhesive foam (one can per 10 m² of layer) and 4 dowels per square metre.

Cutting loss: 10% has been added to the quantity of boards and wool. When ordering building materials, it is recommended to allow for a 5 to 10% waste for insulation, because the boards are cut to fit the framing, corners and penetrations. The excess part of the sprayed foam is also cut off, but this is already included in our price.

Labour: average of construction companies' public price lists: installation of wool and boards per layer, installation of vapour barrier, wind barrier and battens. For the foundation boards, the price of installing an insulation layer has been used.

PUR foam: our price includes materials, installation, generator, cutting and cleanup.

Transport: the price of wool and boards is the shop price excluding delivery. Delivery is paid by the customer according to the shop's delivery price list, or the customer collects the material themselves.

For smaller jobs, a minimum charge applies to PUR foam, which may alter the ratio. Prices vary and depend on the project. The comparison shows a typical ratio, not an offer for a specific job.

How we calculated

Thermal resistance R = thickness of the layer in metres / thermal conductivity λ. For example, 0.100 m / 0.027 = 3.7 m²K/W.

Required layer the thickness with which another material gives the same R-value as our layer: R × λ.

Installed layer is rounded up to the thicknesses of boards on sale, as boards cannot be cut thinner than the manufacturer's thickness. Loose-fill wool and sprayed foam are installed to the required thickness.

Wall and ceiling charts is calculated according to the standard EVS-EN ISO 6946, which adds a correction to the U-value of the wool and boards for joints and air gaps: level 0 is 0 (joints tight), level 1 is 0.01 W/m²K (gaps present, air does not move), level 2 is 0.04 W/m²K (air moves between the warm and cold sides). The result for wool and boards is shown as a range from level 0 to 2. In the case of sprayed foam and blown wool, no gaps are formed and the correction is 0 (level 0).

Installation time for mineral wool and boards is calculated from the labour share of the total cost: the labour price per square metre is divided by the public hourly rate of construction companies (time-based work from €23.40 to €25/h, average €24.20/h), with an 8-hour working day and two builders doing the work. For example, the labour for a stone wool wall costs about €31 per square metre, which for 200 m² comes to about 256 working hours, or 16 working days. With a higher hourly rate, the calculated time would be shorter. For PUR foam, the time shown is a normal working day for Passiivsoojustus.

The comparison uses specific products and their manufacturers' data (October 2026). We calculated the R-value and the required layer ourselves using the formula R = thickness / λ. The layer actually installed is rounded to the thicknesses of boards sold in shops: Paroc Ultra and Estplast EPS 60 in 50 mm steps, Finnfoam FL-300 and Estplast EPS 120 Perimeeter Pluss in 50 and 100 mm. Figures for other products may differ.

Questions

Is PUR foam better than wool?

In terms of thermal conductivity they are similar. The advantage of PUR foam is an airtight layer without joints and quick installation. The advantage of mineral wool is that it is non-combustible.

Should you choose XPS or PUR foam for the foundation?

Both are moisture resistant. Closed-cell PUR foam bonds directly to concrete and covers uneven areas, pipe penetrations and corners without joints.

Can PUR foam be used in areas requiring fire safety?

Yes. The foam is covered with a fire protection board or fire-retardant paint and the structure achieves the required fire resistance. Before the work, we will advise which solution is suitable for your building.

How thick does the layer of PUR foam need to be?

Usually 50 to 200 mm in walls, 200 to 300 mm in sloped ceilings and attics, and an average of 100 mm in foundations.

Not sure which insulation is suitable for your house? Send us the area and layer thickness and we will put together a personal quote for you. If the thickness is not known, we will recommend a suitable one. 25-year manufacturer's warranty on materials and installation
Send enquiry