PUR foam, wool or board: which insulation should you choose?
We compare PUR foam with insulation products common in Estonia in three places: foundations, walls, and sloped ceilings and attics. The figures come from manufacturers' data; we calculated the R-value and required thickness ourselves.
Reading time 6 min · Data as of 18/10/2026Prices, products, thermal conductivity and the 25-year warranty of PUR foam in this comparison belong to Passiivsoojustus. We install Huntsman H2Foam Lite+, H2Foam Lite V24 and Heatlok Shield foam. Prices, products, their indicators and warranty conditions of other PUR foam installers may differ.
When comparing quotes, ask the installer for the product name, declaration of performance (DoP) and a written warranty.
Closed-cell PUR foam, XPS and EPS
The foundation has insulation against the ground and moisture. Here, what matters is how thin a layer can achieve the desired thermal resistance and whether the material can withstand water.
| Property | INSTALLED BY PASSIIVSOOJUSTUSPUR foam, closed cellHuntsman Heatlok Shield | XPS boardFinnfoam FL-300 | EPS boardEstplast EPS 120 Perimeeter Pluss |
|---|---|---|---|
| Thermal conductivity λD, W/mK | 0,027 |
0,036 | 0,035 |
| R value with 100 mm layer, m²K/W | 3,70 |
2,78 | 2,86 |
| Layer required for the same result, R 4.0 | 108 mm |
140 mm2 × 70 mm, R 4.00 according to DoP | 140 mm |
| Layer actually installed | 108 mmsprayed to the required thickness |
150 mm100 + 50 mm boards, 70 mm boards were not available in shops | 150 mmboards 100 + 50 mm |
| Water absorption | Closed cell, water is not absorbed |
0.7% with prolonged soaking | 1.5% with prolonged soaking |
| Joints and uneven surface | Even layer, fills in irregularities |
Board joints, a gap remains on an uneven surface | Board joints, a gap remains on an uneven surface |
| Fixing | Adheres directly to concrete and stone |
Glued or backfilled | Glued or backfilled |
| Reaction to fire | E |
F | E |
| Warranty | 25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman |
Check the manufacturer's and installer's terms | Check the manufacturer's and installer's terms |
Product names are linked to the manufacturer's declaration of performance. Data as of 18/10/2026.
The foam adheres directly to concrete, covers pipe penetrations and corners, and the trench can be backfilled on the same day.
Foundation insulation →PUR foam, rock wool and EPS in the wall
The baseline is our standard wall layer, 200 mm of H2Foam Lite+. The table shows how thick another material must be to provide the same thermal insulation.
| Property | INSTALLED BY PASSIIVSOOJUSTUSPUR foam, open cellH2Foam Lite+ | INSTALLED BY PASSIIVSOOJUSTUSPUR foam, closed cellHeatlok Shield | Rock woolParoc Ultra | EPS boardEstplast EPS 60 |
|---|---|---|---|---|
| Thermal conductivity λD, W/mK | 0,035 |
0,027 |
0,035 | 0,039 |
| Layer required for the same result, R 5.7 | 200 mm |
154 mm |
200 mm | 223 mm |
| Layer actually installed | 200 mmsprayed to the required thickness |
154 mmsprayed to the required thickness |
200 mmboards 150 + 50 mm | 250 mmboards 200 + 50 mm |
| Airtightness | Airtight layer without joints |
Airtight layer without joints |
Joints, requires a separate wind and vapour barrier | Board joints must be sealed |
| Corners, cracks and penetrations | Fills gaps and cracks |
Fills gaps and cracks |
Cracks appear at the cut lines | On an uneven surface, gaps remain |
| Over the years | Does not sag, adheres to the surface |
Does not sag, adheres to the surface |
According to the manufacturer, it will not sag | Does not sag |
| Fixing | Adheres to wood, concrete, stone and metal |
Adheres to wood, concrete, stone and metal |
Requires a framework or fixings | Glued or dowelled |
| Best suited | Timber frame and log walls |
Stone walls and metal structures |
Timber frame | Rendered facade |
| Framing | Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap |
Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap |
The board width must match the framing spacing (565 mm board for 600 mm spacing); in uneven framing, each piece is cut to fit its respective gap | Glued and dowelled to the substrate |
| Warranty | 25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman |
25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman |
Check the manufacturer's and installer's terms | Check the manufacturer's and installer's terms |
Product names are linked to the manufacturer's declaration of performance. Data as of 18/10/2026.
The standard accounts for the fact that joints in wool and boards, as well as air gaps, reduce thermal insulation. Spray foam fills the surface as a single continuous layer without gaps.
Wall insulation →PUR foam, rock wool and cellulose wool in the ceiling
The reference standard is our standard ceiling layer, 250 mm H2Foam Lite+. The table shows how thick the other material must be to provide the same thermal insulation.
| Property | INSTALLED BY PASSIIVSOOJUSTUSPUR foam, open cellH2Foam Lite+ | INSTALLED BY PASSIIVSOOJUSTUSPUR foam, open cellH2Foam Lite V24 | Rock woolParoc Ultra | Cellulose insulationEkovilla YP |
|---|---|---|---|---|
| Thermal conductivity λD, W/mK | 0,035 |
0,038 |
0,035 | 0,038 |
| The layer required for the same result, R 7.1 | 250 mm |
271 mm |
250 mm | 271 mm |
| Layer actually installed | 250 mmsprayed to the required thickness |
271 mmsprayed to the required thickness |
250 mmboards 150 + 100 mm | 271 mmblown in to the required thickness |
| Airtightness | Airtight layer without joints |
Airtight layer without joints |
Joints, requires a separate wind and vapour barrier | Requires a separate wind and vapour barrier |
| Corners, cracks and penetrations | Fills gaps and cracks |
Fills gaps and cracks |
Cracks appear at the cut lines | Fills open cavities |
| Over the years | Does not sag, adheres to the surface |
Does not sag, adheres to the surface |
According to the manufacturer, it will not sag | To be installed with a settlement allowance |
| Installation | Can be sprayed up to 500 m² per day |
Can be sprayed up to 500 m² per day |
Cut and installed by hand | Blown in by machine |
| Framing | Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap |
Suitable for any framing, even in an old house with irregular spacing, the foam fills every gap |
The board width must match the framing spacing (565 mm board for 600 mm spacing); in uneven framing, each piece is cut to fit its respective gap | Requires a closed cavity, does not depend on the spacing |
| Warranty | 25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman |
25 years manufacturer's warranty on material and installation, on Huntsman's terms, written certificate issued by Huntsman |
Check the manufacturer's and installer's terms | Check the manufacturer's and installer's terms |
Product names are linked to the manufacturer's Declaration of Performance or product datasheet. Data as of 18/10/2026.
Lite+ provides the same result with a thinner layer. We use V24 in thicker layers, starting from 250 mm. Both adhere to rafters and boarding and do not sag over the years.
Roof and loft insulation →What we included in the total cost
Materials: the average regular prices at Espak, Bauhof and Decora as of 6 October 2026, the price of EPS 120 Perimeeter Pluss foundation boards from Bauhof as of 18 October 2026, without promotional or loyalty card discounts. All prices are compared excluding VAT.
Additional layers for wool and boards: vapour barrier film in walls and ceiling (with 10% overlap) and vapour barrier tape at 0.5 m per square metre, wind barrier, 50×50 mm battens at 600 mm centres. On the foundation, adhesive foam (one can per 10 m² of layer) and 4 dowels per square metre.
Cutting loss: 10% has been added to the quantity of boards and wool. When ordering building materials, it is recommended to allow for a 5 to 10% waste for insulation, because the boards are cut to fit the framing, corners and penetrations. The excess part of the sprayed foam is also cut off, but this is already included in our price.
Labour: average of construction companies' public price lists: installation of wool and boards per layer, installation of vapour barrier, wind barrier and battens. For the foundation boards, the price of installing an insulation layer has been used.
PUR foam: our price includes materials, installation, generator, cutting and cleanup.
Transport: the price of wool and boards is the shop price excluding delivery. Delivery is paid by the customer according to the shop's delivery price list, or the customer collects the material themselves.
For smaller jobs, a minimum charge applies to PUR foam, which may alter the ratio. Prices vary and depend on the project. The comparison shows a typical ratio, not an offer for a specific job.
How we calculated
Thermal resistance R = thickness of the layer in metres / thermal conductivity λ. For example, 0.100 m / 0.027 = 3.7 m²K/W.
Required layer the thickness with which another material gives the same R-value as our layer: R × λ.
Installed layer is rounded up to the thicknesses of boards on sale, as boards cannot be cut thinner than the manufacturer's thickness. Loose-fill wool and sprayed foam are installed to the required thickness.
Wall and ceiling charts is calculated according to the standard EVS-EN ISO 6946, which adds a correction to the U-value of the wool and boards for joints and air gaps: level 0 is 0 (joints tight), level 1 is 0.01 W/m²K (gaps present, air does not move), level 2 is 0.04 W/m²K (air moves between the warm and cold sides). The result for wool and boards is shown as a range from level 0 to 2. In the case of sprayed foam and blown wool, no gaps are formed and the correction is 0 (level 0).
Installation time for mineral wool and boards is calculated from the labour share of the total cost: the labour price per square metre is divided by the public hourly rate of construction companies (time-based work from €23.40 to €25/h, average €24.20/h), with an 8-hour working day and two builders doing the work. For example, the labour for a stone wool wall costs about €31 per square metre, which for 200 m² comes to about 256 working hours, or 16 working days. With a higher hourly rate, the calculated time would be shorter. For PUR foam, the time shown is a normal working day for Passiivsoojustus.
The comparison uses specific products and their manufacturers' data (October 2026). We calculated the R-value and the required layer ourselves using the formula R = thickness / λ. The layer actually installed is rounded to the thicknesses of boards sold in shops: Paroc Ultra and Estplast EPS 60 in 50 mm steps, Finnfoam FL-300 and Estplast EPS 120 Perimeeter Pluss in 50 and 100 mm. Figures for other products may differ.
Questions
Is PUR foam better than wool?
In terms of thermal conductivity they are similar. The advantage of PUR foam is an airtight layer without joints and quick installation. The advantage of mineral wool is that it is non-combustible.
Should you choose XPS or PUR foam for the foundation?
Both are moisture resistant. Closed-cell PUR foam bonds directly to concrete and covers uneven areas, pipe penetrations and corners without joints.
Can PUR foam be used in areas requiring fire safety?
Yes. The foam is covered with a fire protection board or fire-retardant paint and the structure achieves the required fire resistance. Before the work, we will advise which solution is suitable for your building.
How thick does the layer of PUR foam need to be?
Usually 50 to 200 mm in walls, 200 to 300 mm in sloped ceilings and attics, and an average of 100 mm in foundations.
Paroc, Finnfoam, Estplast and Ekovilla are trademarks of their respective owners. Passiivsoojustus is not affiliated with these companies, and the comparison is based on publicly available data from manufacturers and stores.