PUR foam does not generate water in the structure, but poorly designed insulation can alter temperature distribution, the direction of drying and air movement. The risk of moisture damage depends on the building as a whole: sources of leakage, airtightness, vapour resistance, ventilation and the layering of materials.

Moisture moves in three main ways:

As water leaks: through the roof, a pipe, the facade, the foundation or a penetration.

With air movement: warm and humid indoor air gets through cracks into the cold structure.

As water vapour diffusion: water vapour moves through the material layers due to the pressure difference.

In practice, more moisture can move into the structure through an air leak than by slow diffusion. That is why a continuous air barrier is very important. PUR foam can only improve airtightness if the joints of the walls, roof, windows and penetrations are also sealed.

Difference between open-cell and closed-cell foam

The water vapour resistance factor of H2Foam Lite+ is μ = 2, making the material relatively open to water vapour. Heatlok Shield with μ = 46 means a significantly higher water vapour resistance. The vapour resistance of the entire layer depends not only on the μ-value, but also on the thickness of the layer.

When can wood start to rot?

For biological damage to timber to occur, sufficiently high moisture and time are required. The risk increases if the roof or facade leaks, wood is sealed in before it has dried, vapour-tight layers are in the wrong place, or indoor humidity is high and ventilation is inadequate. The presence of PUR foam is not in itself the cause of damage; the decisive factor is the balance between moisture getting in and drying out.

According to the H2Foam Lite+ technical data sheet, the product can be sprayed onto a wooden substrate with a moisture content of up to 19%. This limit is important for the quality of the installation. Wet or actively decaying wood must not be covered with foam.

Does PUR foam make the house too airtight?

Good airtightness is not a problem in itself. The problem arises when air exchange previously depended on random cracks and the ventilation is not sorted out after renovation. Controlled ventilation removes moisture, odours and carbon dioxide in a controlled manner; a leaky structure does so randomly and along with energy loss.

  • check the bathroom and kitchen extract ventilation;
  • assess the fresh air supply to the bedrooms;
  • if necessary, measure the indoor air CO₂ level and relative humidity;
  • after extensive insulation work, order ventilation balancing;
  • do not close the existing ventilation openings before changing the whole solution.

Does PUR foam prevent mould?

No insulation material provides absolute protection against mould. PUR foam is not a usual nutrient for mould, but given sufficient moisture, mould can grow on dust or other organic dirt accumulated on the surface of the foam. The most important thing is to keep the structure dry, eliminate leaks and ensure working ventilation.

How to reduce the moisture risk before work?

  • Identify all water and air leaks.
  • Measure the moisture of the timber structure.
  • Map the existing vapour-tight layers.
  • Check the watertightness of the roof, facade and foundation.
  • Calculate or estimate the drying direction of the structure.
  • Choose H2Foam Lite+ or Heatlok Shield according to the moisture regime.
  • Fix the ventilation before or immediately after improving the airtightness.

 

Frequently asked questions

 

Does open-cell foam allow wood to dry?

The H2Foam Lite+ value of μ = 2 means that it is more open to water vapour than Heatlok Shield. However, drying depends on the layers of the whole structure, not just the foam.

Can closed-cell foam trap moisture within the structure?

It can restrict the drying of the structure through the insulated surface, as Heatlok Shield's μ is 46. Therefore it must not be installed on a wet structure or used without assessing the drying direction.


Is a vapour barrier required with H2Foam Lite+?

In some structures yes, in others a vapour retarder or a different solution is used. The decision must be based on the whole layer build-up and the indoor climate.


Does foam help against condensation?

Insulation and airtightness can raise the internal surface temperature and reduce condensation on cold surfaces. If water vapour or air movement is managed incorrectly, condensation may occur in another structural layer.


What indoor humidity is safe?

The appropriate relative humidity depends on the temperature, season, and building. It is important to avoid prolonged high humidity and ensure that permanent condensation does not form on windows and cold surfaces.

Related services: roof and loft insulation, wall insulation, PUR foam price