A shipping container is made of thin corrugated steel. Condensation forms in an uninsulated container, and in winter it is just as cold inside as it is outside. Spray PUR foam adheres to the metal, follows the corrugated wall and forms a uniform layer without joints. Read about insulating hangars, warehouses and production facilities on the page insulation of industrial buildings and hangars with PUR foam.
Why does condensation occur in a container?
Condensation occurs when the temperature of a surface drops below the dew point of the surrounding air. At night, the container's metal plating cools rapidly, and the warm, moist air inside condenses on the cold wall and ceiling. Condensation can get onto goods, equipment and structures, and accelerate corrosion. Insulation raises the internal surface temperature and reduces the contact of warm, moist air with the cold metal. Alongside this, indoor air humidity and ventilation must be controlled.
Characteristics of a shipping container
There are many thermal bridges in a container. When insulating from the inside, the formation of an uncontrolled air gap must be avoided, where warm indoor air can enter but cannot be controlled. Spray-applied closed-cell foam follows the corrugated surface and helps to reduce air leaks. The intended use of the container determines the suitable solution: a thin condensation-reducing layer for a storage container, insulation for a year-round workspace, and a wall meeting living space requirements are different constructions. The floor, doors, penetrations, ventilation, fire safety and interior finishing must also be taken into account.
Heatlok Shield or H2Foam Lite+?
For containers, we mostly use closed-cell Heatlok Shield foam. It is a rigid foam that, according to the manufacturer, can be sprayed onto metal. Its λ value is 0.027 W/(m·K), its water vapour resistance factor μ = 46 and its density 36 to 42 kg/m³, so it gives a dense, well-bonding and more vapour-tight layer.
In some cases, open-cell H2Foam Lite+ is also suitable, which can likewise be sprayed onto steel. It is much lighter and more permeable to water vapour, making it suitable when a thicker and lighter layer is required and the moisture management has been planned accordingly.
Surface preparation
- We assess the condition of the surface before starting work on site and let you know if anything needs to be done beforehand.
- The surface must be free from condensation, ice and frost.
- Active leaks and corrosion damage must be repaired first.
- Equipment, lighting and surfaces that are not foamed are to be covered.
- Fire protection, finishing and UV protection are planned prior to installation.
How thick a layer for a container?
The insulation thickness depends on whether the container is a storage unit where condensation needs to be reduced, or a workspace heated all year round. A thin layer can reduce condensation, but does not provide sufficient thermal insulation in a cold winter. We spray closed-cell foam in layers up to 5 cm thick, for example, a 100 mm layer is applied in two layers.
Ventilation and humidity
If wet items are stored in a container, or washing or work is done there, a lot of moisture is generated. Good insulation does not replace extract ventilation. If the humidity in the room stays high, condensation can form on colder surfaces such as doors and uninsulated penetrations.
Common mistakes
- spraying foam onto wet or frozen sheet metal;
- just ceiling insulation, even though the walls, doors and floor remain thermal bridges;
- choosing the layer without knowing the intended use;
- concealing corrosion damage under foam;
- leaving the foam exposed to UV radiation or mechanical impacts;
- underestimating ventilation needs.
Frequently asked questions
Does PUR foam stop condensation in a container?
A continuous layer of insulation reduces surface cooling and the ingress of warm, humid air to the cold metal. To achieve the desired result, the source of moisture, ventilation and thermal bridges must also be addressed.
Is 30 to 50 mm of foam enough for a container?
It depends on the use. A thin layer can be part of a condensation-reducing solution, but for the thermal insulation of a year-round heated room, more insulation and a calculation of the entire structure are often required.
Does Heatlok Shield reinforce metal?
Rigid closed-cell foam may increase the rigidity of some structural parts, but it must not be regarded as a designed reinforcement of a load-bearing structure or as a repair for rust damage.
Related services: insulation of industrial buildings and hangars, garage insulation, PUR foam price