We insulated the ceiling of a house in Tõrva, Valga County, by injecting PUR foam. The attic floorboards stayed in place: we drilled holes in them and injected 200 mm of H2Foam Lite+ foam underneath the boards. The whole job took about an hour.

Client's concern

The ceiling of the house was insulated from the inside with only a 50 mm PIR board, with the interior finish on top of it. This was not enough, and heat was still leaking through the ceiling into the cold attic. Warm air rises, so ceiling insulation has a particularly large effect on how well a house keeps its heat.

On the attic side of the ceiling, there was no finish, only old floorboards. The client did not wish to remove these.

Floorboards of a cold attic with holes drilled for injecting PUR foam
The attic floorboards stayed in place and the foam was injected beneath them.

Why we chose injection

Opening the ceiling or removing floorboards would have meant a lot of extra work. With injection, both the interior finish and the attic floor remained untouched, as the foam is injected into the closed cavity through drilled holes. The existing PIR board remained and now works together with the foam layer.

How the ceiling insulation was done

The end wall of the Tõrva house, a ladder, and the PUR foam hose leading to the attic hatch
The foam hose was taken up to the attic through a hatch in the end wall.

We drilled holes at regular intervals in the attic floorboards so that the foam could reach every part of the cavity. Through the holes, we injected H2Foam Lite+ foam into the cavity between the boards and the ceiling. Initially, the foam is liquid and spreads through the cavity, reaching even the corners. Then the foam expands and fills the cavity from edge to edge. This added a 200 mm layer of foam on top of the ceiling.

Holes drilled into the attic floorboards for ceiling insulation with PUR foam
Holes were drilled into the floorboards at regular intervals.
The installer injects PUR foam through the attic floorboards in Tõrva
Foam was injected through holes into the cavity between the boards and the ceiling.

We checked the filling through the holes. When foam comes out of a hole, that part of the cavity is full and we move on to the next hole.

A drilled hole showing PUR foam at the bottom that filled the ceiling cavity
At the bottom of the hole, foam filling the cavity is visible.
PUR foam came out of the hole, so the ceiling cavity is full at this point
Foam came out of the hole: this part of the cavity is full.

Neither the interior finishes nor the attic floor had to be taken up, and we finished the work in about an hour.

Why H2Foam Lite+

  • Canadian open-cell PUR foam, thermal conductivity 0.036 W/mK.
  • The thermal resistance of a 200 mm foam layer is R 5.56 m²K/W.
  • The foam has integrated wind barrier properties. It stops air movement through the ceiling and the heat stays in the room.
  • The foam is vapour-permeable, so the timber structure can dry out.
  • The foam stays in place within the cavity and does not compress over the years.

Briefly

  • Project: house in Tõrva, Valga County
  • Insulated: ceiling from the attic side, without removing floorboards
  • Method: PUR foam injection through drilled holes
  • Material: H2Foam Lite+
  • Layer thickness: 200 mm, in addition to the existing 50 mm PIR board
  • Working time: about 1 hour
  • Price: based only on the amount of foam installed
  • Warranty: 25-year manufacturer's warranty

Is heat escaping through your ceiling or attic? Read more about PUR foam injection and attic and ceiling insulation or see what makes up the PUR foam price. Send us the area and layer thickness and we will prepare a personal quote for you. If you do not know the thickness, we will recommend a suitable one. We work all over Estonia, including Valga County.